Message name / descriptionASCQASCSense
key
OVERLAPPED COMMANDS ATTEMPTED
Due to a second command being sent from the same host before a
previous command has completed, the previous command has been
aborted. This may also occur when executing off-line commands via the
control panel and DIAG port simultaneously.
Verify that the host software application is supported, has up-to-date
patches, and is correctly configured.
Verify that the library and its components have the current firmware.
004E5
UNCALIBRATED POSITION
System requires calibration. Run the Calibrate Cabinet test from the OCP.
028A5
CLM INVALID START CONDITION
CLM hardware condition is unknown. Run the Robotics to Home Position
test.
E08B5
CLM INVALID COMMAND
CLM hardware commanded to position out of system mechanical limits.
Run the Robotics to Home Position test.
If the problem persists, calibrate the library.
F08B5
IMPORT OR EXPORT ELEMENT ACCESSED
Load port door has been closed.
012B6
POWER-ON, RESET OR BUS DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
00296
POWER-ON RESET OCCURRED.
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
01296
BUS RESET OCCURRED.
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
02296
BUS DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
03296
INTERNAL DEVICE RESET OCCURRED
Informational message. The host user should assume the inventory may
have changed, and should ask the library for that information again.
04296
DOOR WAS OPENED INVENTORY MAY HAVE BEEN CORRUPTED
Close door and retry command after inventory is complete.
00806
SYSTEM STOP BUTTON WAS PRESSED
The STOP button on the control panel was pressed. Press the STOP button
again to start the cabinet. Retry command.
07806