Message name / descriptionASCQASCSense
key
CONFIGURATION SETTINGS CORRUPTED
Reconfigure the library. Run the Calibrate Cabinet Test from the OCP.
0A804
LOW POWER ERROR
Check power connections and power supplies.
0F804
PICKER HARDWARE FAILURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
See
Table
22
814
ROTARY HARDWARE FAILURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
See
Table
22
824
EXTENSION HARDWARE FAILURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
See
Table
22
834
VERTICAL HARDWARE FAILURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
See
Table
22
844
HORIZONTAL HARDWARE FAILURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
See
Table
22
854
DEPTH HARDWARE FAILURE
• Remove any obstructions.
• Run the Robotics Self Test from the OCP.
See
Table
22
874
WARNING SAFE TEMPERATURE EXCEEDED
This is a warning that the temperature in the library exceeds the normal
operational temperature 40
o
C (104
o
F).
00884
MAXIMUM TEMPERATURE EXCEEDED
The robot in the overheated cabinet turns off and remains off until the
temperature returns to an acceptable level. For LTO, the acceptable level
is 52
o
C (127
o
F); for SDLT, the acceptable level is 49
o
C (120
o
F).
• Check whether the air filters need to be replaced.
• Check for fan failure.
• Lower the ambient temperature.
01884
VISION HARDWARE FAILURE
Vision internal failure.
00–FF894
CALIBRATION FAILURE
Check slots, cartridges, targets, and all internal elements. Verify that the
panels are properly seated and that doors are closed.
028A4
HP StorageWorks ESL E-Series Tape Library 129