Control panel message Description Recommended action
00E-Inventory Error during MEBx Execution BIOS information passed to the MEBx resulted in
a failure.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version.
3. If the error still persists, replace the system
board.
00F-Interface Error during MEBx Execution MEBx operation experienced a hardware error
during communication with the ME.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version.
3. If the error still persists, replace the system
board.
100-Front Audio Not Connected Front audio cable has been detached or
unseated from system board.
Reconnect or replace front audio cable.
2E1-MemorySize Error Memory amount has changed since the last boot
(memory added or removed).
The system memory size is dierent from
the last startup. The most common reason is
the removal of memory from the system board.
Press the F1 key to save the memory changes. If
this message persists, verify that the memory
modules are installed correctly.
2E2-Memory Error Memory module conguration failed during boot
up.
1. Ensure memory modules are correctly
installed.
2. Verify proper memory module type.
3. Remove and replace the identied faulty
memory module(s).
4. If the error persists after replacing memory
modules, replace the system board.
2E3-Incompatible Memory Module in Memory
Socket(s) X, X, ...
A memory module in memory socket identied in
the error message is missing critical SPD
information, or is incompatible with the chipset.
1. Verify proper memory module type.
2. Try another memory socket.
3. Replace with a supported module.
2E4-DIMM Conguration Warning The current memory conguration is not
optimized.
Rearrange the DIMMs so that each channel has
the same amount of memory.
2E5-ECC Memory Module Detected on
Unsupported Platform
Recently added memory module(s) support ECC
memory error correction.
1. If additional memory was recently added,
remove it to see if the problem remains.
2. Check product documentation for memory
support information.
2E6–Memory Not Congured Correctly for Proper
MEBx Execution
DIMM1 is not installed. Make sure there is a memory module in
the DIMM1 socket and that it is properly seated.
300–Conguration Change Warning The storage device conguration will be updated
as shown.
Not applicable
301-Hard Disk 1: SMART Hard Drive Detects
Imminent Failure
Hard drive is about to fail. (Some hard drives
have a hard drive rmware patch that will x an
erroneous error message.)
1. Determine if hard drive is giving correct
error message. Run the Drive Protection
System test under using F2 Diagnostics
when booting the computer.
2. Apply hard drive rmware patch
if applicable. (Available at
http://www.hp.com/support.)
3. Back up contents and replace hard drive.
POST numeric codes and text messages 87
Vista de pagina 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 123 124

Comentarios a estos manuales

Sin comentarios