Diagnosing transceiver modules
The device provides the alarm function and digital diagnosis function for transceiver modules. When
a transceiver module fails or inappropriately work, you can check for alarms present on the
transceiver module to identify the fault source or examine the key parameters monitored by the digital
diagnosis function, including the temperature, voltage, laser bias current, TX power, and RX power.
To display alarm information or fault detection parameters for a transceiver module:
Task Command Remarks
Display the current alarm information of the
transceiver module in a specified interface
display transceiver alarm
interface [ interface-type
interface-number ]
Available for all
transceiver modules.
Display the currently measured values of the
detection parameters of the transceiver module
in a specified interface
display transceiver diagnosis
interface [ interface-type
interface-number ]
Available for all
transceiver modules.
# Display the alarm information of the transceiver module plugged in GigabitEthernet 3/1/1.
<Sysname> display transceiver alarm interface GigabitEthernet 3/1/1
GigabitEthernet3/1/1 transceiver current alarm information:
RX loss of signal
Table 17 Command output
Field Remarks
SFP
RX loss of signal Receive (RX) signal is lost.
TX fault TX fault.
RX power high RX power is high.
RX power low RX power is low.
TX power high TX power is high.
TX power low TX power is low.
TX bias high TX bias current is high.
TX bias low TX bias current is low.
Temp high Temperature is high.
Temp low Temperature is low.
Voltage high Voltage is high.
Voltage low Voltage is low.
Transceiver info I/O error Transceiver information read and write error.
Transceiver info checksum error Transceiver information checksum error.
Transceiver type and port configuration
mismatch
Transceiver type does not match port configuration.
Transceiver type not supported by port
hardware
Transceiver type is not supported on the port.
40