Hp Surestore Disk Array 12h and FC60 Manual de usuario Pagina 119

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 466
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 118
Topologies for HP-UX 119
Topology and Array
Planning
Fibre
Channel
cable
No on path to
failed cable;
Yes if array has
dual controller
modules and
alternate paths
have been
configured
I/O operations fail along the path through the failed cable. If the
host has two Fibre Channel adapters connected to a dual-controller
module disk array, the array can be accessed through the
operational path if primary and alternate paths have been
configured in LVM. If so, LVM switches automatically and
transparently to the alternate path. The authorized service provider
hot-swaps the failed cable.
Table 10
High Availability Topology Error Recovery (cont’d)
Failing
component
Continue
after failure What happens and how to recover