Hp Surestore Disk Array 12h and FC60 Manual de usuario Pagina 220

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 466
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 219
220 Configuring the Disk Array
For more information, see "Adding a Global Hot Spare" on page 296
To use SAM, see "Adding a Global Hot Spare" on page 273
Step 10. Install Special Device Files
After binding LUNs, you must install special device files on the LUNs. This makes the LUNs
usable by the operating system.
To install the special device files, type:
insf -e
Step 11. Check Disk Array Status
The final step is to display the disk array status to ensure that all features are enabled and
that the array is working properly.
To display disk array status, type:
amdsp -a <ArrayID>
See Figure 88 on page 284 for a sample status display output that identifies the important
fields and the normal values.
Windows NT and Windows 2000
Perform the following steps to configure the disk for operation on a Windows NT or
Windows 2000 host. Refer to the
HP Storage Manager 60 User’s Guide
for detailed
instructions on performing each of these tasks.
1. Add the disk array to the SM60 management topology.
2. Set up any alert notifications.
3. Rename the disk array.
4. Create the desired volume structure. Replace the default 10 Mbyte volume if necessary.
5. Add hot spares as required.
Vista de pagina 219