334 Status Conditions and Sense Code Information
3F BD The controller has detected a drive with Mode Select parame-
ters that are not recommended or which could not be changed.
Currently this indicates the QErr bit is set incorrectly on the
drive specified in the FRU field of the Request Sense data.
3F C3 The controller had detected a failed drive side channel specified
in the FRU Qualifier field.
3F C7 Non-media Component Failure
The controller has detected the failure of a subsystem compo-
nent other than a disk or controller. The FRU codes and qualifi-
ers indicate the faulty component.
3F C8 AC Power Fail
The Uninterruptible Power Source has indicated that AC power
is no longer present and the UPS has switched to standby
power.
3F C9 Standby Power Depletion Imminent
The UPS has indicated that its standby power source is nearing
depletion. The host should take actions to stop IO activity to the
controller.
3F CA Standby Power Source Not at Full Capability
The UPS has indicated that its standby power source is not at
full capacity.
3F CB AC Power Has Been Restored
The UPS has indicated that AC power is now being used to
supply power to the controller.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier Interpretation