Hp Surestore Disk Array 12h and FC60 Manual de usuario Pagina 82

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 466
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 81
82 Recommended Disk Array Configurations
Maximum Capacity
Note
This configuration is not recommended for environments where high
availability is critical. To achieve high availability each disk in a LUN should be
in a different disk enclosure. This configuration does not achieve that level of
protection.
Hardware Configuration
Two disk array controllers connected directly to host Fibre Channel adapters
Two disk enclosures with ten 73 GByte disks each (20 disks total)
Disk enclosures configured for split-bus mode (two SCSI channels per enclosure)
LUN Configuration
Five RAID 5 LUNs, each comprising four disks (3 data + 1 parity)
Each disk in a LUN is on a separate SCSI bus.
High Availability
Handles the failure of a single disk, single controller, or a single channel
Does not handle a disk enclosure failure, consequently this configuration is NOT
recommended for critical high availability installations.
Expansion requires powering down the disk array, removing terminators and/or
cables from the enclosures, and cabling additional disk enclosures.
Disk Capacity
Maximum capacity 1460 GBytes
Usable capacity 1095 GBytes