Hp Surestore Disk Array 12h and FC60 Manual de usuario Pagina 343

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 466
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 342
Status Conditions and Sense Code Information 343
Managing the Disk Array
on HP-UX
A6 00 Recovered processor memory failure
The controller has detected and corrected a recoverable error
in processor memory.
A7 00 Recovered data buffer memory error
The controller has detected and corrected a recoverable error
in the data buffer memory.
Sense bytes 34-36 will contain the count of errors encountered
and recovered
C0 00 The Inter-controller Communications Have Failed
The controller has detected the failure of the communications
link between redundant controllers.
D0 06 Drive IO Time-out
The controller destination IO timer expired while waiting for a
drive command to complete.
D1 0A Drive Reported Busy Status
A drive returned a busy status in response to a command.
E0 XX Destination Channel Error
XX = 00 through 07 indicates the Sense Key returned by the
drive after a check condition status
XX = 10 indicates that a bus level error occurred
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier Interpretation