Hp Surestore Disk Array 12h and FC60 Manual de usuario Pagina 339

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 466
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 338
Status Conditions and Sense Code Information 339
Managing the Disk Array
on HP-UX
85 01 Drive IO Request Aborted
IO Issued to Failed or Missing drive due to recently failed
removed drive. This error can occur as a result of I/Os in
progress at the time of a failed or removed drive.
87 00 Microcode Download Error
The controller detected an error while downloading microcode
and storing it in non-volatile memory.
87 08 Incompatible Board Type For The Code Downloaded
87 0C Download failed due to UTM LUN number conflict
87 0E Controller Configuration Definition Inconsistent with Alternate
Controller
88 0A Subsystem Monitor NVSRAM values configured incorrectly.
8A 00 Illegal Command for Drive Access
The initiator attempted to pass a command through to a drive
that is not allowed. The command could have been sent in
pass-thru mode or by attempting to download drive microcode.
8A 01 Illegal Command for the Current RAID Level
The controller received a command that cannot be executed on
the logical unit due to its RAID level configuration. Examples
are parity verify or repair operations on a RAID 0 logical unit.
8A 10 Illegal Request- Controller Unable to Perform Reconfiguration
as Requested
The user requested a legal reconfiguration but the controller is
unable to execute the request due to resource limitations.
Table 44
SCSI Sense Codes (cont’d)
Additional
Sense
Code
Additional
Sense Code
Qualifier Interpretation