Installing the Disk Array FC60 Software (HP-UX Only) 215
Installation
swlist
3. Execute the following command to create the required device files (this is not required
if the system was re-booted):
insf -e
4. Run the Array Manager 60 amdsp command to re-scan the system for the array:
amdsp -R
Downgrading the Disk Array Firmware for HP-UX 11.11 Hosts
Controller firmware HP08 is not supported on HP-UX 11.11. If the disk array is being
installed on a host running HP-UX 11.11, it will be necessary to downgrade the controller
firmware to HP03 after installing the software.
1. Identify the version of firmware on the disk array controllers by typing:
amdload -i ArrayID
2. If the controller firmware is HP08, contact HP support for assistance in downgrading
the controller firmware.