HP NonStop Shadowbase Command Definitions
Consumer Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
125
CONTROLFILEEXT <primary extent size, secondary extent size,
maximum extents>
Initial Changed
Version Version Values Default Value Specifications Alter
4.060 16,64,128 2,2,16 - 65535,65535,959 No
Client Server Extended Open Target
This parameter defines the extent size that will be used by AUDMON to
create a CONS CONTROLFILE. The default extent size is (16,64,128).
That is, the primary extent size is 16 pages, the secondary extent size is
64 pages, and the maximum number of extents allocated is 128. The
valid range for the primary extent and secondary is 2 through 65535. The
valid range for the maximum extents is 16 through 959. The parameter
can’t be altered.
CONTROLTYPE { SERIAL }
{ PARALLEL }
Initial Changed
Version Version Values Default Value Specifications Alter
2.000 SERIAL SERIAL, PARALLEL No
Client Server Extended Open Target
This specifies whether interprocess messages are sent serially or in
parallel when using extended Consumers (see the TYPE parameter for
details on extended Consumers and HP NonStop Shadowbase Installation
and Planning Manual for extended Consumer configuration examples). If
no extended Consumers are defined, this parameter is ignored (see the
CONS TYPE parameter).
As extended Consumers are generally obsolete (unless otherwise directed
by HP Shadowbase Support), this parameter should not be used. See
CONS TYPE parameter for more information.
Serial means that only one message at a time is sent. Parallel means that
messages are sent asynchronously (as soon as possible). Parallel is
recommended for high performance needs. Default is SERIAL.
Note: If you have multiple files/tables (fileset) being updated within one
transaction by an application(s), this fileset should all be attached to
the same Consumer. You can configure a basic and related
extended Consumer to process this fileset. Set the
CONTROLTYPE to SERIAL to ensure that modifications to the
target database replay in the same order as they did in the source
database. This may be important for some applications that use
the target database, especially those that are time oriented.