HP NonStop Shadowbase Command Definitions
Consumer Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
128
This specifies the maximum number of failures of a Consumer allowable
within the FAILSPAN period. If the AUD parameter AUTORESTART is
set to ON and FAILMAX is set to 0, the restart attempts will continue
indefinitely. Otherwise, AUDMON will attempt to restart FAILMAX number
of times within the FAILSPAN. Valid values are 0 through 128. A value of
1 disables the restart capability.
Note: This parameter is only used for a stand-alone Consumer (i.e.,i.e.,
CONNECTIONTYPE = DIRECT).
FAILRETRYDELAY seconds
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.900 15 1 3600 Yes
Client Server Extended Open Target
Specifies the number of seconds AUDMON will delay between restart
attempts when the AUDMON AUTORESTART parameter is set to ON and
FAILMAX is set to 0 or greater than 1. The default is 15 seconds. Valid
values are 1 through 3600.
Note: This parameter is only used for a stand-alone Consumer (i.e.,i.e.,
CONNECTIONTYPE = DIRECT).
FAILSPAN seconds
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.900 900 0 32767 Yes
Client Server Extended Open Target
Specifies the span of time over which AUDMON will attempt to
automatically restart failed processes when the AUD AUTORESTART
parameter is set to on and FAILMAX is set greater than 1. The default is
900 seconds (15 minutes). Valid values are 0 through 32767.
Note: This parameter is only used for a stand-alone Consumer (i.e.,i.e.,
CONNECTIONTYPE = DIRECT).
FASTRESTART {ON}
{OFF}
Initial Changed
Version Version Values Default Minimum Maximum Alter
4.092 ON OFF ON No