HP NonStop Shadowbase Command Definitions
Collector Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
85
Version Version Values Default Minimum Maximum Alter
2.000 ON OFF ON Yes
This specifies whether resource usage and system performance statistics
are to be gathered for later display with the STATS COLL command. The
default is ON. See STATS COLL command for more information.
TRACE level_number
Initial Changed
Version Version Values Default Minimum Maximum Alter
2.000 0 disable 0 3 Yes
Disables or sets the trace level for AUDCOM and AUDMON event tracing.
Level_number specifies the level of detail supplied in the trace. 0 through
3 are valid level_numbers. The default is 0, which disables tracing. A
setting of 1 dumps most function names as they are called, 2 dumps
additional function names, and detail for certain functions. A setting of 3
dumps detail on additional functions, including COLL/CONS ipc message
content, and buffers for certain events.
Note: Tracing generates a lot of additional overhead, and will significantly
affect performance. Tracing should never be enabled except under
direction from HP Shadowbase Support.
TRACEFILE filename
Initial Changed
Version Version Values Default Value Specifications Alter
2.000 None Valid file name Include NODE Yes
When tracing is enabled, this identifies the file name where the results are
to be output. The filename can be fully qualified with volume and
subvolume names. The file can be an edit-type disk file, spooler file or the
home terminal. If writing to a disk file and you anticipate a lot of trace
output, pre-creating the disk file with larger extent sizes than the product
will create is recommended. The product creates the disk file with extents
(14 pages, 28 pages, maxextents 559). If the TRACEFILE becomes full,
HP Shadowbase will continue to run, but will not write anymore trace
output.
TURBOMODE { ON }
{ OFF }
Initial Changed
Version Version Values Default Minimum Maximum Alter
2.300 OFF OFF ON No