HP NonStop Shadowbase Command Definitions
Collector Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
72
This defines the time that the Collector is to wait before outputting an EMS
message to indicate that the Collector restart position is lagging behind.
The valid range is 0 through 32767 seconds. The default is 900 (15
minutes). If the Collector lags behind and an EMS message is issued and
then it catches back up and then lags behind again shortly thereafter, it
won't issue another behind EMS until CHKPTWARNRATE time has
passed by. Note that it will issue a message to indicate that it has caught
up during the next RESTARTFILE refresh after CHKPTTIME has passed
by. In v4.090 the maximum value was increased from 32767 to
2147483647 (from a 16-bit value to a 32-bit value).
CHKPTWARNTDIFF <number of seconds>
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.960C 4.090 8100 0 disable 2147483647 Yes
This is the lag time used by the Collector to determine if the restart
position is lagging behind the current audit trail read position. The restart
position is determined to be lagging behind if the difference between the
time of last read audit trail record and the time of the current audit trail
restart position is equal to or greater than CHKPTWARNTDIFF.
As of release v3.980B the CHKPTWARNTDIFF parameter minimum value
can now be set to 0. This will disable the check the Collector performs to
insure that the normal restart position is advancing. Thus the valid range
has changed from 1 through 32767 seconds, to 0 through 2147483647
seconds. The default is 8100 seconds (2.25 hours).
In v4.090 the maximum value was increased from 32767 to 2147483647
(from a 16-bit value to a 32-bit value).
Note: That the EMS messages associated with this checking have been
changed to “critical”.
Note: That long-running transactions could result in EMS messages being
issued if the CHKPTWARNTDIFF is set lower than the time it takes
for the transaction to complete.
CHKPTWARNTDIFFB <number of seconds>
Initial Changed
Version Version Values Default Minimum Maximum Alter
3.980B 4.090 8100 0 disable 2147483647 Yes
For a bi-directional replication environment this is the lag time used by
the Collector to determine if the restart position is lagging behind the
current audit trail read position. The restart position is determined to be