HP Integrity NonStop H-Series Guía de usuario Pagina 48

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 346
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 47
HP NonStop Shadowbase Command Definitions
Monitor Command Descriptions
HP NonStop Shadowbase Command Reference Manual—785421-002
39
This directs listing the output to a named file. If this option is omitted,
listing output is directed to the AUDCOM list file; this is typically the home
terminal.
An example of the results of doing an SHOW AUD command is shown
below:
AUD OBJECT SETTINGS:
ADTWARNRATE 900
ADTWARNTDIFF 900
AUTORESTART OFF
AUTOSTOP OFF
BACKUPCPU ?
CONFIRMCONTROL OFF
CONFIRMSHUTDOWN OFF
HISTORYRATE 0
MAXCOLL 1
MAXCONS 1
MAXDBSSPEC 128
MAXPULSESTATS 2
MAXQMGR 0
MAXQUERYDUR 60
MONITORRATE 300
NORUNTIMEOUT 900
PULSEMAINTTIME 00:00
PULSERETENTION 7
STATICTMFSERVE OFF
STATSRESET OFF
STATSRESETTIME MONTH(ALL),DAY(DAILY),HOUR(00:00)
TRACE OFF
TRACEFILE ?
UNDOMODE OFF
ALLOWUSERID ?
SHUTDOWN Command
The SHUTDOWN command is used to shut down the HP Shadowbase
environment. It stops the Collectors and Consumers. When all these
processes are down, it stops AUDMON.
SHUTDOWN [!]
!
If the ! (now) option is used, the CONFIRMSHUTDOWN parameter will not
be considered, and the command will be run without additional
confirmation.
Vista de pagina 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 345 346

Comentarios a estos manuales

Sin comentarios