1. Click the Device Configuration tab.
2. Select a device from the Device List.
3. Right-click the selected device.
4. Choose Apply Template to apply a single template to the device, or choose Apply Template
Group to apply a template group to the device.
The Template Apply Summary window displays, listing the specific details of the template application
process. The Description column lists whether the template or template group was successfully
applied.
Template settings can be overridden by changes to the product settings made at the product control-
panel. If the settings in a template are not being applied as expected, it might be necessary to reapply
the template to the product.
External Database Configuration
The primary means for configuring DSS to use an external database, which is any database other
than the one DSS installs by default, is during installation. It is also possible to change the database
that DSS uses, either from the default database to an external database, or from one external
database to another, after software installation. This is done by running a utility that allows the
administrator to change the connection string that DSS uses to connect to its database. This must
only be done with CAREFUL CONSIDERATION of the following point:
●
Data that exists in the database which DSS is currently using will be lost and not transferred to
the new database. This includes, but is not limited to, DSS address books and job logs.
To change the database connection string after installation:
1. Run the utility
<install folder>\scripts\ExternalDbConfigurationUtility
\Hp.Dss.Utility.ExternalDbConfiguration.exe
This utility provides the same UI for setting the database connection string as seen during
installation. See step seven of
Installer screens and options on page 37 for instructions.
2. Stop and then re-start the DSS service
3. Remove all the FutureSmart devices from DSS, and then add them back to DSS.
106 Chapter 3 Installation and configuration ENWW